LNG QUALITY SPECIFICATIONS

Value

Unit

Specifications

Notes

Wobbe Index

KWh/Nm3

13.066-16.328

Gross Calorific Value (GCV)

KWh/Nm3

11.131-12.647

The Operator may consider the possibility of accepting a cargo with GCV in the range 11.011KWh/Nm3 to 11.131KWh/Nm3 or 12.647 KWh/Nm3 to 12.986 KWh/Nm3, if after unloading this cargo and mixing with the stored LNG in terminal tanks, the GCV of the resulting LNG will be within the mentioned range.

LNG Density

Kg/m3

430 – 478

The Operator may consider the possibility of accepting a cargo in the range 420.3 Kg/m3 to 430 Kg/m3 or 478 Kg/m3 to 483.1 Kg/m3, if after unloading this cargo and mixing with the stored LNG in terminal tanks, the Density of the resulting LNG will be within the mentioned range.

Molecular Weight

Kg/Kmol

16.52 – 18.88

Methane

% mol

85.0 min

97.0 max

The Operator may consider the possibility of accepting a cargo with Methane concentration in the range 80 to 85 % mole or 97 to 99.8 % mole, if after unloading this cargo and mixing with the stored LNG in terminal tanks, the value of Methane concentration of the resulting LNG will be within the mentioned range.

i-Butane & n- Butane

% mol

4 max

i- Pentane & n-Pentane

% mol

2 max

Nitrogen

% mole

1.24 max

Hydrogen sulfide (H2S)

mg/Nm3

5.0 max

Total sulphur

mg/Nm3

30.0 max

Temperature

0C

-159.5 max

The average temperature of LNG in all tanks of LNG vessel at the loading port should not be greater than -159.5°C.

LNG Tank Pressure

mbar(g)

100 max

On arrival